Founded in 1999, SpectraSensors, Inc. a division of Endress+Hauser Group is the leading global provider of laserbased on-line analyzers for process control and monitoring applications with an installed base of over 6,000 units. A commercial spin off of the NASA-Caltech Jet Propulsion Laboratory. The Company’s products are designed specifically to meet product specifications in natural gas production, transport, storage, distribution, gas processing, refining, petrochemical, and specialty and bulk gas production.
SpectraSensors is headquartered in Houston, Texas, US A with its technology development and manufacturing in Rancho Cucamonga, California. The Company has nearly 90 full-time employees, including 38 with engineering and science degrees. Approximately, one third of these employees are located in Houston, TX with responsibilities in the areas of sales, marketing, service, software and application engineering. The other two thirds are located in Rancho Cucamonga, CA.
SS500/SS2000 Channel Moisture Analyzer
Features
- Typical Measurement Ranges – 2-20lbs, 2-50lbs, 2-100lbs/MM scf**
- Typical Repeatability – +/- 10 ppmv or +/- 2% of reading
- Measurement Response Time 0.25-2 seconds*
- Environmental Temperature Range of -4 to 122 degrees F
- Class I, Div 2 and Class I, Div 1 options
- NIST -traceable calibration
- Analog and serial outputs for remote monitoring
SS1000 Portable H2O Gas Analyzer
Benefits
Light weight, easy to handle, battery-powered H2O analyzer, used to verify measurements and for
spot-checking when other methods provide questionable results.
Features
- Typical Measurement Ranges of Medium and High Precision options up to 100lbs/MM scf**
- Typical Repeatability
- Medium Precision – +/-10 ppmv or +/-2% of reading
- High Precision – +/-4 ppmv or +/-2% of reading
- Measurement Response Time – 0.25-2 seconds*
- Environmental Temperature Range -4 to 122 degrees F
- Power Supply
- 100-240 VAC, 50-60Hz – Standard
- 12-Volt Sealed Lead-Acid Battery (Approx. 8 hours usage time per charge)
SS3000 Dual Channel (H2O/H2O)
Benefits
Cost effective measurement system which enhances
savings by incorporating two sensors in one.
Features
- Typical Measurement Ranges
- H2O – 0.5-20lbs, 0.5-50lbs, 0.5-100lbs/MM scf**
- Typical Repeatability
- H2O – +/-4ppmv or +/-2% of reading
- Measurement Response Time – 0.25-2 seconds*
- Environmental Temperature Range –
- -4 – 122 degrees F (15 – 140 degrees F optional)
SS2000E H2O Single Channel Analyzer
Features
- Typical Measurement Ranges
- H2O – 0.5-20lbs, 0.5-50lbs, 0.5-100lbs/MM scf**
- Typical Repeatability
- H2O – +/- 4 ppmv or +/- 2% of reading
- Measurement Response Time – 0.25-2 seconds*
- Heated and unheated Stainless Steel Sample Conditioning Enclosures with NEM A – 4X System Rating
- Optional RS 485 and Ethernet Communications
2-Pack (H2S, H2O) Analyzer Systems
Features
- Typical Measurement Range
- H2S – 0-20 +/-0.5 ppmv**
- H2O – 0-20+/- 0.2 lb/MM scf**
- Measurement Update Time
- H2S – <5 seconds*
- H20 – 1 Second*
- Environmental Temperature Range –
- -4 – 122 degrees F (15 – 140 degrees F optional)
* Total system response is dependent on flow rate and
sample system volume
**Consult factory for additional ranges.
Overview on benefits
Benefits
- Rapid Response Time – analyzer takes four measurements per second with a laser and detector and immediately averages the results.
- No Consumables – The analyzer’s sensor never touches the gas stream.
- Payback – quickly pays for itself by doing away with expensive consumables, extra sensors and labor.
- No Interference – does not suffer from contamination or drift due to vapor impurities such as glycol, methanol, amines, hydrogen sulfide or mercaptans.
| | | |